Astm a792 az 50.
Minimum roof insulation thickness ibc.
Aluminum zinc alloy coated steel.
Base flashing shall be of either corrosion resistant metal of minimum nominal 0 019 inch 0 5 mm thickness or mineral surfaced roll roofing weighing not less than 77 pounds per 100 square feet 4 kg m 2.
Fasteners for asphalt shingles shall be galvanized stainless steel aluminum or copper roofing nails minimum 12 gage 0 105 inch 2 67 mm shank with a minimum 3 8 inch diameter 9 5 mm head of a length to penetrate through the roofing materials and a minimum of 3 4 inch 19 1 mm into the roof sheathing.
If your community receives a lot of snow during the winter local building codes may require a minimum roof pitch for snow load which ensures that heavy snows will slide off.
Specific insulation requirements of section c402 2 thermal requirements of either.
Continuous insulation zones ashrae 90 1 ashrae 189 1 igcc ibc iecc 2004 2007 2010 2013 2016 2009 2011 2014 2012 2015 2009 2012 2015 0 25 1 15 20 2 15 20 25 3 15 20 25 4 15 20 302535 5 15 20 302535 6 15 20 3035 7 15 20 3540 25 8 20 3540 25 minimum r value non residential above roof deck.
In some regions however local weather may dictate roof pitch.
2015 code requires walls to be insulated with a minimum of r 20 or r 13 5 13 5 means r 13 cavity insulation plus r 5 insulated sheathing.
For pre formed metal shingle systems.
High yield copper for metal sheet roof covering systems.
Cap flashing shall be corrosion resistant metal of minimum nominal 0 019 inch 0 5 mm thickness.
The pitch of your roof is generally determined by the span of the sidewalls and the desired roof height.
Astm b370 minimum 16 oz sq.
Astm b209 0 024 inch minimum thickness for roll formed panels and 0 019 inch mini mum thickness for press formed shingles.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Where the roof sheathing is less than 3 4 inch 19 1 mm thick the nails.
If structural sheathing covers 40 or less of the exterior continuous insulation r value shall be permitted to be reduced by no more than r 3 in the locations where structural sheathing is used to maintain a consistent total sheathing thickness.
Both codes provide specific instructions for re roofing projects and both are clear that replacements must comply with insulation r value requirements if the roof system is part of the building thermal envelope and contains insulation entirely above the deck.
Or component performance alternative of section c402 1 5 roof solar reflectance and thermal emittance fenestration in building envelope.